SURGICAL CRAFT
Year : 2015  |  Volume : 31  |  Issue : 2  |  Page : 156-159
 

Use of a vegetable model as a training tool for PCNL puncture


Department of Urology, NU Hospitals, Bangalore, Karnataka, India

Date of Web Publication1-Apr-2015

Correspondence Address:
Dr. Maneesh Sinha
Department of Urology, NU Hospitals, CA 6, 15th Main, 11th Cross, Padmanabhanagar, Bangalore - 560 070, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-1591.152922

Rights and Permissions

 
   Abstract 

Introduction: Training residents to perform a PCNL puncture is hampered by the non-availability of a good inanimate model that can be used for demonstration and practice. The ethics of surgical training during actual surgeries is being questioned and the role of simulation is increasingly important. Virtual reality trainers, however, are prohibitively expensive and the use of animal models is fraught with regulatory and ethical concerns. We have devised a model that can be used to teach the concept of depth perception during a PCNL puncture.
Methods: A bottle gourd was used to mimic the posterior abdominal wall. Cotton pledgets dipped in intravenous contrast were fitted into 4 mm holes made at staggered levels in the bottle gourd which was strapped onto the operating table with the cotton pledgets facing away from the surgeon. Surgeons with varying degrees of experience made fluoroscopy-guided punctures onto the cotton pledgets. We recorded the time taken for puncture in seconds and the distance of the needle exit site from the center of the cotton ball. Speed was measured by recording the fluoroscopy time in seconds on the C-arm. Accuracy was documented by using a Vernier caliper to measure the distance from the edge of the target to the actual puncture. One second of fluoroscopy time and 0.1 mm distance were each given one point. The total points accumulated over a set of 10 punctures was added to give a total score. Longer fluoroscopy times and inaccurate punctures resulted in higher scores.
Results: A surgeon with more than 1000 PCNLs to his credit had a score of 99. The average score of five residents was 555.
Conclusion: The bottle gourd model provides an ethically acceptable, inexpensive, easy to replicate model that can be used to train residents in the PCNL puncture.


Keywords: Bottle gourd, PCNL, puncture


How to cite this article:
Sinha M, Krishnamoorthy V. Use of a vegetable model as a training tool for PCNL puncture. Indian J Urol 2015;31:156-9

How to cite this URL:
Sinha M, Krishnamoorthy V. Use of a vegetable model as a training tool for PCNL puncture. Indian J Urol [serial online] 2015 [cited 2023 Mar 28];31:156-9. Available from: https://www.indianjurol.com/text.asp?2015/31/2/156/152922



   Introduction Top


Learning how to make a percutaneous nephrolithotomy (PCNL) puncture remains one of the more difficult aspects of endourology training. Converting the visuo-spatial information provided by the fluoroscopic image into the psychomotor ability to make an accurate puncture is always a struggle for the trainee. Most modern surgeons have learnt their punctures on real patients. In the charged atmosphere of an actual operating theater, the usual situation is of an extremely anxious trainee attempting a puncture under the supervision of an impatient trainer on an absolutely clueless patient!

One way of circumventing this problem is to train on a simulator. In the past decade, simulator training has been accepted as an adjunct to surgical training. [1] Available simulators are virtual reality models (VR) or animal models. [2],[3],[4] VR models give a good visual and haptic feedback but are not universally accessible due to prohibitive costs. Frugality in training models is an important concern in order to make them widely available. Animal models tend to be cumbersome and entail elaborate precautions and regulations. Keeping these considerations in mind, we have developed an easily replicable vegetable simulator which can orient the trainee to depth and distance perception during a PCNL puncture.


   Methods Top


There are two essential components of a PCNL puncture that a simulator must reproduce. The first is a tissue-like medium for the needle to go through and the second is a target representing the calyx. After trying a few fruits and vegetables, we hit upon the bottle gourd as a suitable candidate. While selecting the vegetable, the emphasis was on easy, universal availability. Solid tissue with consistency close to human tissue was also a prerequisite. The bottle gourd was finally chosen because its depth corresponded to the measured depth of the calyx on the computed tomography (CT) scan. Its length allowed multiple targets to be created on a single specimen. Additionally, being a relatively drier vegetable, it was less messy in the operating theater. The force needed during puncture was slightly more than what is experienced in patients, but it served the primary purpose of helping the trainee coordinate two-dimensional visuospatial fluoroscopic information with three-dimensional hand-eye movements.

The second component was to create the target. Analysis of normal CT images at our institution yielded the depth and width of a normal adult posterior calyx to be 5-7 cm and 2-6 mm, respectively. We routinely use 14 guage, 7.5 cm intracath needles to make our PCNL punctures and we have infrequently needed longer needles. The model, however, works equally well with the longer two- or three-piece needles used by most urologists. Shan et al. measured the skin to calyx distance on dorsal CT scans to be 7.85 cm in the upper calyx and 9.25 cm in the lower calyx. [5] However, these patients had a mean body mass index of 28.66 and an abdominal girth of 100.79 cm and were, therefore, much larger than our average patients. Licheng describes mean puncture depths to be 52.54 cm on standard dose CT. [6] The flexibility of our model allows a surgeon to choose the size of the vegetable on his own. While the bottle gourd itself is available in diameters of 5 to over 10 cm, the plant world offers us an infinite variety of options to choose from.

The targets were made using contrast-impregnated, peanut-sized cotton balls embedded at staggered levels into one side of the bottle gourd. This replicated the calculus or contrast-filled calyx very realistically. Finally, to simulate the prone patient, the bottle gourd was strapped onto the operating table using adhesive plaster at either end. The surgeon stood on the side away from the targets and passed a needle under fluoroscopic guidance to target the cotton pledgets [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6].
Figure 1: Raw materials needed include the bottle gourd, cotton pledgets, radiographic contrast, needles and a measuring scale

Click here to view
Figure 2: The model after punctures

Click here to view
Figure 3: Radiographic appearance of model before puncture

Click here to view
Figure 4: Radiographic appearance of model with the needle punctures

Click here to view
Figure 5: The surgeon stands on the side away from the targets to make the punctures

Click here to view
Figure 6: Direct visualization of the exit site in incorrect punctures helps the trainee orient himself to the information provided by the fluoroscopic images

Click here to view


We used the triangulation technique of puncture, very similar to the technique described by Shergill. [7] With the C-arm in 0° , the needle is inserted to the edge of the desired target. The C-arm is then rotated 10-30° toward the surgeon. In this view, if the needle tip appears to have overshot the desired target, it lies superficial and if it appears not to have reached the target, it is pointing too deep. The correct orientation is achieved when in both 0 and 30, the needle tip appears to be pointing just at the edge of the target.

The outcomes were measured in terms of speed and accuracy. The speed was measured by recording fluoroscopy time in seconds on the C-arm. Accuracy was documented by using a Vernier caliper to measure the distance from the edge of the target to the actual puncture. One second of fluoroscopy time and 0.1 mm distance were each given one point. The total points accumulated over a set of 10 punctures were added to give a total score. A greater score meant a poorer outcome.


   Results and Discussion Top


The model and scoring systems were subjected to reverse validation. Three consultants with reasonable skills in PCNL and five resident Urology trainees were asked to make these punctures. The senior consultant with over 1000 PCNLs to his credit had a score of 99. The two junior consultants who were performing PCNLs on a regular basis had scores of 146 and 250. The mean score of five residents was 555. A simple way of analyzing the scores would be to imagine all punctures being accurate. The senior consultant would have taken less than 10 s for each puncture. Each resident would use up 1 min of fluoroscopy time to get their punctures right.

This model does have limitations. It does not replicate normal respiratory movements. We believe this feature to be unnecessary in a simulator. Once the needle passes across the renal capsule, the needle moves along with the respiratory movements and there is minimal relative movement between the calyx and the needle tip. However, we do acknowledge that the absence of respiratory movements is a serious limitation of this model and the trainee will need to reorient to respiratory excursions once actual PCNL punctures are attempted. Additionally, the rind of the bottle gourd allows less maneuverability than the posterior abdominal wall and renal capsule. We have circumvented this problem by coring out some of the outer skin at the site of the entry of the needle.

The advantages of this model are that it is inexpensive and easily replicable. It is also versatile as almost any vegetable of appropriate size and consistency can be used. We aim to prospectively validate this model to see if it can improve the trainee's ability to make a PCNL puncture. Further external validation is also needed before this model can be widely used.

 
   References Top

1.
Carter FJ, Schijven MP, Aggarwal R, Grantcharov T, Francis NK, Hanna GB, et al. Consensus guidelines for validation of virtual reality surgical simulators. Surg Endosc 2005;19:1523-32.  Back to cited text no. 1
    
2.
Häcker A, Wendt-Nordahl G, Honeck P, Michel MS, Alken P, Knoll T. A biological model to teach percutaneous nephrolithotomy technique with ultrasound- and fluoroscopy-guided access. J Endourol 2007;21:545-50.  Back to cited text no. 2
    
3.
Jutzi S, Imkamp F, Kuczyk MA, Walcher U, Nagele U, Herrmann TR. New ex vivo organ model for percutaneous renal surgery using a laparoendoscopic training box: The sandwich model. World J Urol 2014;32:783-9.  Back to cited text no. 3
    
4.
Zhang Y, Yu CF, Liu JS, Wang G, Zhu H, Na YQ. Training for percutaneous renal access on a virtual reality simulator. Chin Med J (Engl) 2013;126:1528-31.  Back to cited text no. 4
    
5.
Shan CJ, Mazzucchi E, Payao F, Gomes AC, Baroni RH, Torricelli FC, et al. The skin-to-calyx distance measured by renal CT scan and ultrasound. Int Braz J Urol 2014;40:212-9.  Back to cited text no. 5
    
6.
Licheng J , Yidong F , Ping W , Keqiang Y , Xueting W , Yingchen Z, et al. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL). Indian J Med Res 2014;139:386-92.  Back to cited text no. 6
[PUBMED]  Medknow Journal  
7.
Shergill IS, Abdulmajed MI, Moussa SA, Rix GH. The 3-finger technique in establishing percutaneous renal access: A new and simple method for junior trainees. J Surg Educ 2012;69:550-3.  Back to cited text no. 7
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6]

This article has been cited by
1 Simulation-Based Training Models for Urolithiasis: A Systematic Review
Abdullatif Aydin, Umair Baig, Ahmed Al-Jabir, Kemal Sarica, Prokar Dasgupta, Kamran Ahmed
Journal of Endourology. 2021; 35(7): 1098
[Pubmed] | [DOI]
2 A new model of inexpensive portable homemade PERC Mentor (IPHOM) and its validation
Abhishek Shukla, Gurwinder Sethi, Ananya Dutta, Puneet Aggarwal, Ayon Gupta
African Journal of Urology. 2021; 27(1)
[Pubmed] | [DOI]



 

Top
Print this article  Email this article
 

    

 
   Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (1,514 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
   Methods
    Results and Disc...
    References
    Article Figures

 Article Access Statistics
    Viewed6111    
    Printed116    
    Emailed1    
    PDF Downloaded261    
    Comments [Add]    
    Cited by others 2    

Recommend this journal

Fosfocin