Indian Journal of Urology Users online:337  
IJU
Home Current Issue Ahead of print Editorial Board Archives Symposia Guidelines Subscriptions Login 
Print this page  Email this page Small font sizeDefault font sizeIncrease font size
ORIGINAL ARTICLE
Year : 2019  |  Volume : 35  |  Issue : 4  |  Page : 282-286

Diagnostic precision of sentinel lymph node biopsy in penile cancer


Department of Urology, Instituto Nacional de Cancerología, Bogotá, Colombia

Correspondence Address:
Jose Gustavo Ramos
Department of Urology, Instituto Nacional de Cancerología, Bogotá
Colombia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/iju.IJU_79_19

Rights and Permissions

Introduction: Sentinel lymph node biopsy (SLNB) was designed as a minimally invasive method for evaluation of nodal involvement in patients with penile cancer and nonpalpable lymph nodes. Nevertheless, SLNB is not used in a regular basis due to the lack of studies that adequately characterize the performance of this procedure. The purpose of this study was to evaluate the diagnostic performance of SLNB in patients with infiltrative penile carcinoma without palpable inguinal lymph nodes in a Colombian population. Materials and Methods: This is a retrospective observational study of 89 patients diagnosed with infiltrative penile squamous cell carcinoma with nonpalpable inguinal lymph nodes. These patients underwent partial or complete penectomy, along with SLNB, between 2008 and 2017. Those individuals with a positive SLNB underwent inguinal lymphadenectomy, while those with a negative SLNB were followed on a quarterly basis with a physical examination and imaging to assess relapse. Statistical analysis was done using the STATA 14 software. A contingency table was made to calculate sensitivity, specificity, positive predictive value, negative predictive value, and exactitude, each one with its own confidence interval (CI) of 95%. Results: There was an average follow-up of 31.4 months, and all 89 patients were evaluated; most primary tumors were T2 (55%), followed by T1 (37%), all of which were subclassified as T1b and T3 (8%). Tumours were most frequently located in the glans (43%). All patients were classified as cN0 and underwent SLNB. Sixty-one patients (69%) tested negative in the SLNB, four of whom (6%) presented with lymph node relapse. On the other hand, 28 patients (31%) tested positive in the SLNB and consequently underwent inguinal lymphadenectomy, seven of whom had negative lymph nodeinvolvement (25% false positives). According to the results, the sensitivity was 84% (95% CI, 65.3–93.6) and the specificity was 89% (95% CI, 79.4–94.7), with a false-negative rate of 6.5%. Conclusions: The SLNB using radiotracer can be a useful method for lymph node staging in patients with penile cancer and nonpalpable lymph nodes when performed in experienced centers.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed348    
    Printed7    
    Emailed0    
    PDF Downloaded35    
    Comments [Add]    

Recommend this journal

 

HEALTHWARE INDIA