Indian Journal of Urology Users online:1131  
IJU
Home Current Issue Ahead of print Editorial Board Archives Symposia Guidelines Subscriptions Login 
Print this page  Email this page Small font sizeDefault font sizeIncrease font size
SYMPOSIUM
Year : 2012  |  Volume : 28  |  Issue : 1  |  Page : 65-70

Laparoendoscopic single-site donor nephrectomy


Department of Urology, Muljibhai Patel Urological Hospital, Nadiad, Gujarat, India

Correspondence Address:
Arvind P Ganpule
Muljibhai Patel Urological Hospital, Nadiad - 387 001, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-1591.94960

Rights and Permissions

A donor would prefer a minimally invasive procedure because of lesser morbidity, this may be the reason that laparoscopic donor nephrectomy (LDN) rates have exponentially increased. The rationale dictates that a virtually scarless surgery would be most beneficial to this patient subgroup. In this article, we review the approach, instrumentation, dissection and retrieval issues and the results of laparoendoscopic single-site donor nephrectomy (LESS-DN). The existing literature on LESS-DN was reviewed in Pubmed. The various access sites described for LESS-DN include the umbilicus and Pfannenstiel incision. The steps of LESS-DN duplicate those of standard LDN. There is a paucity of studies comparing LESS-DN with LDN, particularly randomized studies. The most challenging step of LESS-DN is graft retrieval. Authors have described a variety of methods for graft retrieval which include manual methods, and those using retrieval bags. In the majority of the studies, the graft retrieval time is longer in comparison to standard LDN. However, the graft outcome in recipients is comparable. In this article, we also allude to the complications mentioned in various series. LESS-DN is currently an evolving procedure. The procedure requires a high level of skills in laparoscopic surgery. The choice of access site, access site ports and the type of instruments to be used is a matter of surgeon preference. Although the warm ischemia time in most of the series is longer in LESS-DN, this has not translated into poor recipient outcomes. Further work needs to be done to make the retrieval quick.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2220    
    Printed101    
    Emailed0    
    PDF Downloaded139    
    Comments [Add]    

Recommend this journal

 

HEALTHWARE INDIA