Objective : Topical hemostatic agents are used in a wide variety of surgical settings, and the evolution of this class of surgical tools is an interesting topic. We reviewed and outlined the historical progress of topical hemostats into present day surgery and urology, and highlight opportunities for future research.
Materials and Methods : A MEDLINE search of all available literature concerning several classes of topical hemostatic agents was performed. Fibrins sealants, Gelatin sponge hemostatics, cyanoacrylate adhesives, oxidized regenerated cellulose, and microfibrillar collagen were included. References were chosen from a broad range of surgical literature.
Results : Topical hemostatic agents have historically taken advantage of a wide variety of mechanisms for hemostasis. Fibrin sealants have a rich history and large potential for further applications. Gelatin sponge hemostatics have been widely used since their introduction, but have changed little. Cyanoacrylate adhesives have a unique mechanism and opportunity for novel applications of existing products. Oxidized cellulose was original in the use of plant-based components. Microfibrillar collagen hemostats have evolved to a wide variety of formats.
Conclusions : A review of the evolution of topical hemostatic agents highlights opportunities for potential novel research. Fibrin sealants may have the most opportunity for advancement, and understanding the history of these products is useful. With the drive in urology for minimally invasive surgical techniques, adaptation of topical hemostatic agents to this surgical approach would be valuable and offers an opportunity for novel contributions.


Keywords: Fibrin sealant, gelfoam, hemostatic agents, microfibrillar collagen, oxidized regenerated cellulose


How to cite this article:
Sundaram CP, Keenan AC. Evolution of hemostatic agents in surgical practice. Indian J Urol 2010;26:374-8

How to cite this URL:
Sundaram CP, Keenan AC. Evolution of hemostatic agents in surgical practice. Indian J Urol [serial online] 2010 [cited 2014 Jul 29];26:374-8. Available from: http://www.indianjurol.com/text.asp?2010/26/3/374/70574



   Introduction Top


As any surgeon would agree, hemostasis is of critical importance during all surgical procedures. A fundamental principle of good surgical technique is minimization of blood loss, and present day surgeons have a wide variety of agents and tools to aid them in this endeavor. Few urologic surgeons would be eager to undertake renal procedures without the ubiquitous electrosurgical unit. Although used less frequently than simple electrocautery, topical hemostatic agents are useful in minimizing blood loss and in turn surgical morbidity. Although no aid in hemostasis can negate the importance of good surgical technique, even the most talented surgeon has encountered persistent bleeding which has required focused attention. Often a topical hemostatic agent is helpful in these situations, and the evolution of these agents is an interesting topic in surgical history. In this article, we review the history and evolution of selected hemostatic agents and highlight areas with potential for future advancements. Special attention is paid to the fibrin sealants, which have an interesting history and significant potential for novel urologic research.


   A Review of Hemostasis Top


Hemostasis is a complex process requiring the delicately coordinated activation of platelets and plasma clotting factors to form a platelet-fibrin clot. [1] This can be divided into two distinct processes, primary and secondary hemostasis. Primary hemostasis results in the formation of soft platelet plugs, which in turn are stabilized and cross-linked during secondary hemostasis. Of central importance in both primary and secondary hemostasis is the activation of the clotting cascade, which can be broken down into two basic pathways, the intrinsic pathway and the extrinsic pathway.[2] The intrinsic pathway is activated by collagen, which is exposed when a blood vessel is damaged. The extrinsic pathway is similarly activated by tissue damage and the resultant release of tissue factor. The intrinsic and extrinsic pathways converge into the common pathway, which begins with the conversion of Factor X to Xa, and ultimately results in the conversion of prothrombin to thrombin, which is integral in clot stabilization via fibrin. [3] The common pathway is facilitated by Factor V, which surgeons often think of due to the relatively common heritable coagulation disorder, Factor V Leiden. [4] The physiology of hemostasis is well-understood, and historically many topical hemostatic agents have been designed to mimic or exploit the enzymes and molecules central to the process.


   Fibrin Sealants Top


Topical hemostatic agents in the modern surgical era can be traced to 1909, when Bergel first discussed the use of topical fibrin for hemostasis. [5] This evolved into a class of preparations known as fibrin sealants. Early fibrin sealants combined bovine thrombin with human plasma for topical application. [6] Widespread surgical usage was initially limited, but in 1938 purified thrombin became available through advancements in the technology of protein separation. [7] That technology accelerated research and development of fibrin sealants, and reports of apparently successful usage of such agents began to appear in the surgical literature in the 1940s. Young and Medawar reported the use of fibrin sealant to repair peripheral nerves in 1940. [8] In 1944, Cronkite et al. reported the usage of combined fibrinogen and thrombin in improving skin graft survival and adhesion in the grafting of soldiers with severe burn injuries. [9]

Although exciting, the early formulations were fraught with problems, namely their potentially infectious nature. All early fibrin sealants were derived from human plasma components, and as with all human-derived products at the time, preparations of human fibrinogen and thrombin were a source of transmission of viral hepatitis, and some early patients treated with fibrin-based hemostatic agents contracted hepatitis. In an effort to minimize the risk of viral transmission, bovine thrombin was substituted for human thrombin in many subsequent preparations. This resulted in some patients developing coagulopathies associated with the use of bovine thrombin related to immune-mediated production of thrombin and Factor V inhibitors. [10],[11] The risk of viral transmission, in addition to the coagulopathies, seen with bovine thrombin usage led to significantly decreased appeal, and work on these sealants essentially ceased for a number of years.

Interest was revived in the late 1960s with advancements in technology allowing for the isolation and concentration of clotting factors from human plasma. Cryoprecipitate became widely available, and in 1972, Matras combined cryoprecipitate with purified bovine thrombin to produce the first modern iteration of a fibrin sealant. [12] Research continued, and the first commercially available fibrin sealant was approved in Europe in 1982. Despite reported success among European and Japanese surgeons with use of fibrin sealants, the American Food and Drug Administration (FDA) did not follow in approving the product because of the perceived risk of viral transmission from the pooled plasma component. [7] As use by foreign surgeons continued, American surgeons implemented the use of noncommercial forms of fibrin sealant throughout the 1990s. Most of these surgeons generated sealants which were created through combining patient's own plasma clotting factors through autologous donation, with bovine thrombin. [13] Progress was made in reducing the risk of viral transmission through human blood products, and ultimately in 1998, Tisseel and Hemaseel fibrin sealants were approved for clinical use by the American FDA. The most recent variation on fibrin sealants came in 2003, when the American Red Cross, in conjunction with OMRIX Biopharmaceuticals, released Crosseal, a fibrin sealant manufactured entirely from nonanimal components. Crosseal contains human fibrinogen and thrombin, and lacks the bovine aprotinin component found in the other fibrin sealants. [14]

Published reports of clinical applications for fibrin sealants were initially largely limited to cardiac and vascular surgery, oral and maxillofacial surgery, and reconstructive plastic surgery, but recently, more and more applications are being discussed in the urologic literature. Mueller et al. presented an interesting series of eight patients in which the fibrin sealant Tisseel was used to create ureteral obstruction during laparoscopic pluck nephroureterectomy. [15] As a hemostatic agent, Zhang et al. published a modified technique of renal artery anastamosis utilizing fibrin sealant in a series of renal transplantations in rats. [16] Gopal et al. and Ambriz-Gonzalez et al. reported decreased fistula and complication rates, respectively, when fibrin sealants are used over suture lines during hypospadias repair. [17],[18] Further publications in the urologic literature report the utility of fibrin glue in tubeless percutaneous renal surgery, as well as in the repair of complicated vesicovaginal fistulas as an alternative to the martius flap. [19],[20]

Although fibrin sealant was one of the first modern hemostatic agents to be used in clinical practice, the slow development of the technology and initial obstacles to FDA approval and subsequent limited availability have lead to a relative paucity of prospective clinical research with fibrin sealants. The utility of effective hemostasis in a topical biologic agent combined with effective tissue sealant is of undeniable interest to any urologic surgeon. As an understudied material, fibrin sealants offer an exciting arena of potentially novel clinical urologic research. Given that Tisseel and other sealants are now widely commercially available, the potential for large prospective randomized clinical trials in common urologic procedures, such as percutaneous renal surgery and ureteral anastamosis, is quite exciting. Perhaps even more interesting than the hemostatic uses of fibrin sealants are the therapeutic possibilities. The potential for further evolution in the application of fibrin sealants has been shown in biomaterials research utilizing fibrin sealants for topical delivery of antibiotics, chemotherapeutics, and analgesics, which offers yet another interesting opportunity for novel research. [21]


   Gelatin Hemostatic Agents Top


Fibrin sealants were one of the first modern hemostatic agents, but their initially limited use opened the door for other novel hemostatic products, many of which are now more familiar to most surgeons. Gelatin-based hemostatic agents are abundant in modern operating rooms, and were first introduced in the 1940s as Gelfoam. In their fundamental form, gelatin-based hemostatic agents have undergone very little evolution since their introduction. Gelfoam and Surgifoam are still offered in similar preparations as their initial release. Gelfoam is a purified pork skin gelatin, and its hemostatic properties, although not entirely understood, are felt to be more physical rather than related to direct effects on the clotting cascade. [22] Gelfoam can be used in several ways, either in dry sponge form, moistened with injectable sodium chloride solution, or, commonly, saturated with topical purified thrombin. The combined application with topical thrombin is one of the few advancements made with gelatin-based hemostatic agents. The addition of thrombin can enhance the hemostatic properties of gelatin sponge hemostatics, but plain Gelfoam or Surgifoam is affordable and readily accessible. It is considered a mediocre hemostat by some surgeons, but has been noted to have success when used in its plain form for hemostasis in tubeless percutaneous nephrolithotomy. [23]

A property of gelatin sponge hemostatics is the ability to absorb upwards of 40 times its weight in blood or fluids, and its capacity to expand up to 200% in vivo. [22] This can be construed as a negative property in some settings. Another major advancement in the field of gelatin-based hemostatic agents came in the development of the product Floseal. Approved for commercial use in the US in 1999, Floseal combines human-derived thrombin with bovine-derived gelatin matrix granules which are mixed at the time of use. [24] The major evolution of this product is the liquid nature of Floseal vs gelatin sponge, as well as a novel crosslinking of the gelatin matrix granules that minimizes in vivo expansion of the product. [25] Although this is not an important property of a hemostatic agent in some surgical approaches, the liquid nature of the product does facilitate application, especially in minimally invasive surgery. As with gelatin sponge agents, Floseal is absorbable and well-tolerated. Rare reports of abscess formation or granuloma formation have been reported with the use of gelatin-based agents; however, some of these have been attributed to the radiologic appearance on postoperative imaging of gelatin sponges. [26],[27] Accessibility, ease of use, and effective hemostasis make gelatin-based hemostatic agents a popular tool in reducing surgical morbidity from blood loss.


   Cyanoacrylate Adhesives Top


Cyanoacrylate adhesives were developed by Dr. Harry Coover of Kodak Laboratories in 1942, during experiments to design a clear plastic suitable for gun sights. The material was unsuccessful in this application, and was abandoned. [28] In 1949, Airdis synthesized cyanoacrylate, and recognizing its unique properties, submitted the material for US patent.[29] In 1959, Coover et al. reported on the adhesive properties of cyanoacrylates, and suggested their application as surgical adhesives. [30] In 1965, Watson and Maguda used cyanoacrylate adhesive for tympanic membrane repair, and there were reports that cyanoacrylates were used as tissue adhesives and hemostatic agents on battlefields during the Vietnam War. [31] Eastman submitted an application for approval to the FDA for cyanoacrylates as a wound adhesive in 1964, but issues with tissue irritation and brittleness prevented approval. Finally, in 1998, after significant redesign, cyanoacrylates were approved by the FDA in the form of 2-octyl cyanoacrylate. Marketed as Dermabond, 2-octyl cyanoacrylate, has been shown to be a good tissue adhesive, and to have antimicrobial properties.

Liquid cyanoacrylate consists of cyanoacrylate monomers, which polymerize into long chains in the presence of hydroxyl ions. Water containing human tissue activates the polymerization of cyanoacrylate monomers, and is bonded together as the glue rapidly sets. The property of nearly instantaneous bonding makes cyanoacrylates an effective hemostatic agent and tissue adhesive. Currently, multiple brands and formats of cyanoacrylate adhesives are available, and are widely used for corneal perforation repair, skin laceration repair, esophageal and gastric variceal repair, skin grafting, and vascular repair. Testini et al. reported significantly reduced morbidity when using human fibrin glue or N-butyl-2-cyanoacrylate adhesive for mesh fixation during inguinal hernia repair when compared with suture.[32] Elmore et al. report the use of 2-octyl-cyanoacrylate in sutureless circumcision with good result, negating the risk of suture tracks or sinuses. [33] Aning et al. recently reported a novel use of cyanoacrylate adhesive for the percutaneous ablation of a late urinary fistula after partial nephrectomy.[34] Cyanoacrylates are becoming increasingly popular for the sutureless closure of small skin incisions, and as surgeons from all fields become more comfortable with the properties of these adhesives, cyanoacrylates are likely to be put to increasingly innovative uses.


   Oxidized Regenerated Cellulose Top


A new iteration of topical hemostatic was launched into the clinical market in 1960 with the release of Surgicel. This topical agent was entirely unique in the market, as it was not derived from human or animal sources. Surgicel is a plant-based topical hemostatic, made by regenerating pure plant-derived cellulose into a knitted fabric which is then oxidized.[35] The oxidized cellulose fabric can be topically applied and acts as a scaffold for clot formation. Oxidized regenerated cellulose topical hemostatic agents have, like gelatin-based products, evolved little since their introduction, but are still quite effective and commonly used. Surgicel bolsters are a popular adjuvant to controlling surgical bleeding during partial nephrectomy. [36] Another common feature between the oxidized cellulose hemostatics and gelatin-based hemostatics is an appearance on postoperative imaging that can be concerning for abscess. [37] Surgicel can in fact have a ring enhancing appearance on computed tomography scan, and perhaps some of the most clinically significant advancements in the use of this hemostatic are in better understanding of its radiological features, thereby reducing the morbidity of unnecessarily intervening on a presumed abscess.


   Microfibrillar Collagen Top


A more recently developed and approved addition to the market of hemostatic agents is collagen-based products. Avitene, a topical microfibrillar collagen hemostatic, was introduced in the US in the early 1970s. Microfibrillar collagen products are made by purifying bovine collagen and processing it into microcrystals, which can then be manipulated into hemostatic agents in a wide variety of formats. The brand Avitene was first launched in a flour form, and it is still commonly used in the topical powder form. All manner of collagen-based hemostatics enjoyed widespread early use as they were felt to be more effective than gelatin-based hemostats. Collagen-based products activate the intrinsic pathway of the coagulation cascade, whereas gelatin hemostats are thought to induce hemostasis through physical properties alone. [38] In several randomized trials, primarily in the cardiothoracic surgical literature, microfibrillar collagen hemostats have been shown to be superior to oxidized cellulose in hemostasis, and indeed were shown to have statistically significant reductions in measured blood loss when compared with oxidized cellulose.[38] The primary improvements and changes made in the field of collagen hemostatics have been in the release of new formats. As previously stated, the first collagen hemostat, Avitene was initially available in a flour form, and today the product line has expanded to a nonwoven web material, as well as a sponge format. In May 2000, the most recent addition, the sponge form Avitene Ultrafoam Collagen, was approved by the American FDA. [39]


   Summary Top


Fibrin sealants, gelatin-based products, oxidized cellulose, and collagen products are the major classes of topical hemostatic agents that have evolved over the last 100 years. Three of these classes have been relatively static since their development, with changes mostly to format and preparation. The evolution of fibrin sealants, conversely, has been slow but steady over the last century, and holds the great promise for future adaptations. This is especially exciting, when considered in the context of current surgical practice. Surgery of all kinds, but even more so Urologic surgery, is undergoing a period of rapid growth and evolution of techniques, instrumentation, and theory, driven by the modern push for minimally invasive surgery. As new devices and surgical systems reach clinical practice with impressive speed, there needs to be a concurrent pressure for the adaptation of surgical tools and drugs. Hemostasis is always critically important in any surgical approach, and it can prove particularly challenging in minimally invasive surgery. For example, in laparoscopic partial nephrectomy, control of surgical bleeding can be the most technically challenging step in the operation. [40] Well-designed, effective topical hemostatic agents are invaluable in minimally invasive surgical practice. Multiple different mediums and classes of topical hemostatics are prime subjects for adaptation to urologic surgical approaches of the future. In particular, fibrin sealant hemostatic agents have a rich history and large potential for further reinvention.

 
   References Top

1.Boucher BA, Traub O. Achieving hemostasis in the surgical field. Pharmacotherapy 2009;29:2S-7S.  Back to cited text no. 1      
2.Hess JR, Brohi K, Dutton RP, Hauser CJ, Holcomb JB, Kluger Y, et al. The coagulopathy of trauma: a review of mechanisms. J Trauma 2008;65:748-54.  Back to cited text no. 2      
3.Rubin E, Gorstein F, Rubin R, Schwarting R, Strayer D. Rubin′s Pathology Clinicopathologic Foundations of Medicine. 4 th ed. Baltimore: Lippincott, Williams and Wilkins; 2005.  Back to cited text no. 3      
4.Franchini M, Lippi G. Factor V Leiden and hemophilia. Thromb Res 2010;125:119-23.   Back to cited text no. 4      
5.Bergel S. Uber die wirkung des fibrins. Dtsch Med Wochenschr 1909;35:663-5.  Back to cited text no. 5      
6.Spotnitz WD. Fibrin sealant: past, present, and future: a brief review. World J Surg 2010;34:632-4.  Back to cited text no. 6      
7.Jackson MR. Fibrin sealants in surgical practice: An overview. Am J Surg 2001;182:1S-7S.  Back to cited text no. 7      
8.Young J, Medawar P. Fibrin suture of peripheral nerves. Lancet 1940;275:126-32.  Back to cited text no. 8      
9.Cronkite E, Lozner E, Deaver J. Use of thrombin and fibrinogen in skin grafting. JAMA 1944;124:976-8.  Back to cited text no. 9      
10.Muntean W, Zenz W, Edlinger G, Beitzke A. Severe bleeding due to factor V inhibitor after repeated operations using fibrin sealant containing bovine thrombin. Thromb Haemost 1997;77:1223.  Back to cited text no. 10      
11.Muntean W, Zenz W, Finding K, Zobel G, Beitzke A. Inhibitor to factor V after exposure to fibrin sealant during cardiac surgery in a two-year-old child. Acta Paediatr 1994;83:84-7.  Back to cited text no. 11      
12.Matras H. The use of fibrin sealant in oral and maxillofacial surgery. J Oral Maxillofac Surg 1982;40:617-22.  Back to cited text no. 12      
13.Albala DM. Fibrin sealants in clinical practice. Cardiovasc Surg 2003;11:5-11.  Back to cited text no. 13      
14.Schexneider KI. Fibrin sealants in surgical or traumatic hemorrhage. Curr Opin Hematol 2004;11:323-6.  Back to cited text no. 14      
15.Mueller TJ, Dajusta DG, Cha DY, Kim IY, Ankem MK. Ureteral fibrin sealant injection of the distal ureter during laparoscopic nephroureterectomy-a novel and simple modification of the pluck technique. Urology 2010;75:187-92.  Back to cited text no. 15      
16.Zhang G, Zhao H, Sun ZY. A modified technique of renal artery anastomosis in rat kidney transplantation. Eur Surg Res 2009;44:37-42.  Back to cited text no. 16      
17.Gopal SC, Gangopadhyay AN, Mohan TV, Upadhyaya VD, Pandey A, Upadhyaya A, et al. Use of fibrin glue in preventing urethrocutaneous fistula after hypospadias repair. J Pediatr Surg 2008;43:1869-72.  Back to cited text no. 17      
18.Ambriz-Gonzαlez G, Velαzquez-Ramνrez GA, Garcνa-Gonzαlez JL, de Leσn-Gσmez JM, Muciρo-Hernαndez MI, Gonzαlez-Ojeda A, et al. Use of fibrin sealant in hypospadias surgical repair reduces the frequency of postoperative complications. Urol Int 2007;78:37-41.  Back to cited text no. 18      
19.Choe CH, L′Esperance JO, Auge BK. The use of adjunctive hemostatic agents for tubeless percutaneous nephrolithotomy. J Endourol 2009;23:1733-8.  Back to cited text no. 19      
20.Safan A, Shaker H, Abdelaal A, Mourad MS, Albaz M. Fibrin glue versus martius flap interpositioning in the repair of complicated obstetric vesicovaginal fistula. A prospective multi-institution randomized trial. Neurourol Urodyn 2009;28:438-41.  Back to cited text no. 20      
21.Soon AS, Stabenfeldt SE, Brown WE, Barker TH. Engineering fibrin matrices: The engagement of polymerization pockets through fibrin knob technology for the delivery and retention of therapeutic proteins. Biomaterials Nov 13 2009.  Back to cited text no. 21      
22.Pfizer. GELFOAM package insert. Available from: http://media.pfizer.com/files/products/uspi_gelfoam_sponge.pdf [last cited on 2009].  Back to cited text no. 22      
23.Singh P, Mandhani A. Use of absorbable gelatin sponge as an adjunct to "totally tubeless percutaneous nephrolithotomy". Arch Esp Urol 2009;62:423-9.  Back to cited text no. 23      
24.Baxter. FLOSEAL [Hemostatic matrix] instructions for use. 2005.  Back to cited text no. 24      
25.Renkens KL Jr, Payner TD, Leipzig TJ, Feuer H, Morone MA, Koers JM, et al. A multicenter, prospective, randomized trial evaluating a new hemostatic agent for spinal surgery. Spine (Phila Pa 1976) 2001;26:1645-50.  Back to cited text no. 25      
26.Eklof O, Lebowitz RL. Localized intra- and retroperitoneal gas collections following intraoperative use of surgical gelatine sponge. Pediatr Radiol 1981;11:1-4.  Back to cited text no. 26      
27.Sandrasegaran K, Lall C, Rajesh A, Maglinte DT. Distinguishing gelatin bioabsorbable sponge and postoperative abdominal abscess on CT. AJR Am J Roentgenol 2005;184:475-80.  Back to cited text no. 27      
28.Hayes, Sharon Caskey. "Discovery of Super Glue helped land Coover in National Inventors Hall of Fame", Kingsport Times-News, July 11, 2004.  Back to cited text no. 28      
29.Ardis AE. US Patents No. 2467926 and 2467927. 1949.  Back to cited text no. 29      
30.Coover HN, Joyner FB, Shearer NH. Chemistry and performance of cyanoacrylate adhesives. Soc Plast Eng 1959; 15: 413-7.  Back to cited text no. 30      
31.Sierra DH, Saltz, Renato. Surgical adhesives and sealants: current technology and applications. Lancaster, PA: Technomic Publishing Company, Inc.; 1996.  Back to cited text no. 31      
32.Testini M, Lissidini G, Poli E, Gurrado A, Lardo D, Piccinni G. A single-surgeon randomized trial comparing sutures, N-butyl-2-cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair. Can J Surg 2010;53:155-60.  Back to cited text no. 32      
33.Elmore JM, Smith EA, Kirsch AJ. Sutureless circumcision using 2-octyl cyanoacrylate (Dermabond): appraisal after 18-month experience. Urology 2007;70:803-6.  Back to cited text no. 33      
34.Aning JJ, Stott MA, Watkinson AF. Glue ablation of a late-presentation urinary fistula after partial nephrectomy. Br J Radiol 2009;82:e246-8.  Back to cited text no. 34      
35.Hong YM, Loughlin KR. The use of hemostatic agents and sealants in urology. J Urol 2006;176:2367-74.  Back to cited text no. 35      
36.van Dijk JH, Pes PL. Haemostasis in laparoscopic partial nephrectomy: current status. Minim Invasive Ther Allied Technol 2007;16:31-44.  Back to cited text no. 36      
37.Young ST, Paulson EK, McCann RL, Baker ME. Appearance of oxidized cellulose (Surgicel) on postoperative CT scans: similarity to postoperative abscess. AJR Am J Roentgenol 1993;160:275-7.  Back to cited text no. 37      
38.Sirlak M, Eryilmaz S, Yazicioglu L, Kiziltepe U, Eyileten Z, Durdu MS, et al. Comparative study of microfibrillar collagen hemostat (Colgel) and oxidized cellulose (Surgicel) in high transfusion-risk cardiac surgery. J Thorac Cardiovasc Surg 2003;126:666-70.  Back to cited text no. 38      
39.Bard. Bard Announces FDA Clearance of Avitene Ultrafoam Collagen to Stop Bleeding During Surgery. Available from: http://www.findarticles.com/p/articles/mi_m0EIN/is_2000_March_9/ai_60007565/ [last cited on 2009].   Back to cited text no. 39      
40.Msezane LP, Katz MH, Gofrit ON, Shalhav AL, Zorn KC. Hemostatic agents and instruments in laparoscopic renal surgery. J Endourol 2008;22:403-8.  Back to cited text no. 40      



This article has been cited by
1 Topical Hemostatic Therapy in Surgery: Bridging the Knowledge and Practice Gap
Aryeh Shander,Lewis J. Kaplan,Michael T. Harris,Irwin Gross,Nimesh P. Nagarsheth,Jeffrey Nemeth,Sherri Ozawa,Jeffrey B. Riley,Maria Ashton,Victor A. Ferraris
Journal of the American College of Surgeons. 2014;
[Pubmed]
2 Topical hemostatic agents: A systematic review with particular emphasis on endoscopic application in GI bleeding
Barkun, A.N. and Moosavi, S. and Martel, M.
Gastrointestinal Endoscopy. 2013; 77(5): 692-700
[Pubmed]
3 Topical hemostatic agents: a systematic review with particular emphasis on endoscopic application in GI bleeding
Alan N. Barkun,Sarvee Moosavi,Myriam Martel
Gastrointestinal Endoscopy. 2013; 77(5): 692
[Pubmed]
4 Taking tissue adhesives to the future: from traditional synthetic to new biomimetic approaches
Lígia Pereira Bré,Yu Zheng,Ana Paula Pêgo,Wenxin Wang
Biomaterials Science. 2013; 1(3): 239
[Pubmed]
5 Acute respiratory failure from Surgifoam expansion after anterior cervical surgery
Branko Skovrlj,Justin R. Mascitelli,Martin B. Camins,Amish H. Doshi,Sheeraz A. Qureshi
Journal of Neurosurgery: Spine. 2013; 19(4): 428
[Pubmed]
6 Efficiency of TachoSil® in hemostasis and surgical sealants | [Eficiencia de TachoSil® en la hemostasia y sellado quirúrgicos]
Rubio-Terrés, C., Rubio-Rodríguez, D.
Pharmacoeconomics - Spanish Research Articles. 2012; 9(1): 11-20
[Pubmed]
7 Screw fixation is superior to N-butyl-2-cyanoacrylate in onlay grafting procedure: A histomorphologic study
Baş, B., Özden, B., Bekçioǧlu, B., Sanal, K.O., Gülbahar, M.Y., Kabak, Y.B.
International Journal of Oral and Maxillofacial Surgery. 2012; 41(4): 537-543
[Pubmed]
8 Eficiencia de TachoSil® en la hemostasia y sellado quirúrgicos
Carlos Rubio-Terrés,Darío Rubio-Rodríguez
PharmacoEconomics Spanish Research Articles. 2012; 9(1): 13
[Pubmed]
9 Screw fixation is superior to N-butyl-2-cyanoacrylate in onlay grafting procedure: a histomorphologic study
B. Bas,B. Özden,B. Bekçioglu,K.O. Sanal,M.Y. Gülbahar,Y.B. Kabak
International Journal of Oral and Maxillofacial Surgery. 2012; 41(4): 537
[Pubmed]
10 Efficacy and biocompatibility of jason® collagen fleece for haemostasis after iliac crest harvesting of autologous cancellous bone - an observational clinical study
Fleege, C. and Schmidt, J. and Schmidt, I. and Zukowski, D. and Rauschmann, M.
European Musculoskeletal Review. 2012; 7(4): 240-242
[Pubmed]
11 Hemostats, sealants, and adhesives: A practical guide for the surgeon
Spotnitz, W.D.
American Surgeon. 2012; 78(12): 1305-1321
[Pubmed]



 

Top
Print this article  Email this article
Previous article Next article

    

 
   Search
 
   Next article
   Previous article 
   Table of Contents
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (218 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
    Introduction
    A Review of Hemo...
    Fibrin Sealants
    Gelatin Hemostat...
    Cyanoacrylate Ad...
    Oxidized Regener...
    Microfibrillar C...
    Summary
    References

 Article Access Statistics
    Viewed3141    
    Printed191    
    Emailed4    
    PDF Downloaded226    
    Comments [Add]    
    Cited by others 11    

Recommend this journal

HEALTHWARE INDIA